Figure 5-3 PCI-X Power Supply LED Locations
1
2
Table 5-3 PCI Power Supply LEDs
Description
State
Driven By
LED
All output voltages generated by the power supply are
within limits.
On Green
Each supply
Power
1
Power to entire system has been removed.
Off
The temperature within the power supply is above the
lower threshold.
Flash Yellow
Each supply
Fault
2
The temperature of the power supply is approaching the
thermal limit.
On Yellow
Power supply has shut down due to an over temperature
condition, a failure to regulate the power within expected
limits, or a current-limit condition.
Flash Red
Normal operation.
Off
System and PCI I/O Fan LEDs
There is a single three-color LED on each system and PCI I/O fan.
Server LED Indicators
125