Table 5-1 Front Panel LEDs
(continued)
Description
Status
LED
At least one MP is installed and active
Green
(solid)
MP Status
No MPs are installed or at least one is installed but not active
Off
Cabinet overtemp condition exists
Red (flashing)
Cabinet shutdown for thermal reasons
Red
(solid)
Cabinet fan slow or failed, master slave failover.
Yellow
(flashing)
FPGA detects no MPs present or functioning
Yellow
(solid)
Cell power on
Green
(solid)
Cell 0 and Cell 1
Cell power off
Off
Cell fault. Cell powered off due to power problem or HPMC/MC
event from cell
Red
(solid)
Cell fault warning
Latches not latched, LPM not ready, VRMs reporting not good or
OT Cell fan slow/failed
Yellow
(flashing)
Cell not present
Yellow (Solid)
User requests locator ON and specifies (1 - 72) hour off timeout.
Default timeout is 24 hours.
Blue
(flashing)
Locate
Timeout. Or user requests locator off.
Off
Bulk Power Supply LEDs
There is a single three-color LED on each bulk power supply.
Server LED Indicators