Figure 5-5 Cell Board LED Locations
V3P3 Standby (Green)
V12 Standby (Green)
Cell Power (Green)
Attention (Yellow)
Standby (Green)
Voltage Margin
Active (Red)
Attention (Yellow)
Cell Power (Green)
BIB (Green)
SM (Green)
Manageability Fab (Green)
PDHC Heartbeat (Green)
Table 5-5 Cell Board OL* LED Indicators
Description
State
Driven by
LED
Location
3.3 V Standby and Cell_Pwr_Good
On Green
Cell LPM
Power
On cell board
(located in the server
cabinet)
3.3 V Standby off, or 3.3 V Standby on
and no Cell_Pwr_Good
Off
Safe to remove the cell board from the
system
Flash Yellow
MP via GPM
Attention
PCI-X OL* Card Divider LEDs
The PCI-X OL* card LEDs are located on each of the 16 PCI-X slot dividers in the PCI-X card
cage assembly area. The green power LED indicates whether power is supplied to the card slot.
The yellow attention LED states are defined in
Table 5-8 “OL* LED States”
.
Server LED Indicators
127
Summary of Contents for Integrity rx7640
Page 8: ...8 ...
Page 12: ...12 ...
Page 13: ...List of Examples 4 1 Single User HP UX Boot 101 7 1 Single User HP UX Boot 181 13 ...
Page 14: ...14 ...
Page 42: ...42 ...
Page 88: ...88 ...
Page 130: ...Figure 5 8 Core I O Button Locations OLR MP Reset 130 Server Troubleshooting ...
Page 140: ...140 ...
Page 176: ...176 ...
Page 184: ...184 ...
Page 191: ...Figure C 3 Planning Grid Computer Room Layout Plan 191 ...