of the system. For systems running a single partition, one MP/SCSI board is required. A second
MP/SCSI board is required for a dual-partition configuration, or if you want to enable primary
or secondary MP failover for the server.
Connections to the MP/SCSI board include the following:
•
DB9 connector for Local Console
•
10/100 Base-T LAN RJ45 connector (for LAN and Web Console access)
This LAN uses standby power and is active when AC is present and the front panel power
switch is off.
•
Internal LVD Ultra 320 SCSI channel for connections to internal mass storage
•
Internal SE Ultra SCSI channel for connection to an internal removable media device.
LAN/SCSI Connections
The LAN/SCSI board is a PCI form factor card that provides the basic external I/O connectivity
for the system.
Connections to the LAN/SCSI board include the following:
•
PCI-X to PCI-X bridge for multi-device compatibility
•
Two LVD Ultra 320 SCSI channel controllers: one for internal connection to one of the HDD
devices, and the other is available for connection to an external device
•
Two 10/100/1000 Base-T LAN RJ45 connectors
The primary LAN interface is located on the LAN/SCSI board installed in the right-most slot
when viewing the system from the back.
Management Processor Access
NOTE:
The primary MP/SCSI board is located in the lower MP/SCSI board slot.
Setting Up the Customer Engineer Tool (PC)
The CE Tool is usually a laptop. It allows communication with the Management Processor (MP)
in the server. The MP monitors the activity of either a one-partition or a multiple-partition
configuration.
During installation, communicating with the MP enables such tasks as:
•
Verifying that the components are present and installed correctly
•
Setting the MP LAN configurations
•
Shutting down cell board power
Establish communication with the MP by connecting the CE Tool to the local RS-232 port on the
MP core I/O card.
Setting CE Tool Parameters
After powering on the CE Tool, ensure the communications settings are as follows:
•
8 data bits/ no parity
•
9600 baud
•
na (Receive)
•
na (Transmit)
If the CE Tool is a laptop using Reflection 1, ensure communications settings are in place, using
the following procedure:
1.
From the Reflection 1 Main screen, pull down the Connection menu and select Connection
Setup.
2.
Select Serial Port.
Cabling and Power Up
75
Summary of Contents for Integrity rx7640
Page 8: ...8 ...
Page 12: ...12 ...
Page 13: ...List of Examples 4 1 Single User HP UX Boot 101 7 1 Single User HP UX Boot 181 13 ...
Page 14: ...14 ...
Page 42: ...42 ...
Page 88: ...88 ...
Page 130: ...Figure 5 8 Core I O Button Locations OLR MP Reset 130 Server Troubleshooting ...
Page 140: ...140 ...
Page 176: ...176 ...
Page 184: ...184 ...
Page 191: ...Figure C 3 Planning Grid Computer Room Layout Plan 191 ...