Determining whether a component is hot-pluggable
Before removing any serviceable part, determine whether the part is hot-pluggable or non-hot-pluggable.
•
If the component is hot-pluggable, a power shutdown of the device is not required for replacement
of the part.
•
If the component is not hot-pluggable, the device must be powered down.
CAUTION:
Be sure the replacement is available before removing a component or blanking panel from the chassis.
Open slots dramatically impact air
fl
ow and cooling within the enclosure.
Table 3 Component hot-pluggability
Component
Hot-pluggable
Non hot-pluggable
Redundant power supply module
X
Redundant fan module
X
MSA array controller
(dual-controller con
fi
gurations)
X *
Fibre Channel I/O module
(dual-controller con
fi
gurations)
X *
SCSI I/O module
X
MSA chassis
X
MSA array controller
(single-controller con
fi
gurations)
X
Fibre Channel I/O module
(single-controller con
fi
gurations)
X
* Before removing one of the two controllers or Fibre Channel I/O modules in an operational dual-controller
MSA, the controller being removed must
fi
rst be disabled. For more information, see
Replacing the controller,
controller cache, or controller battery
.
maintenance and service guide
69
Summary of Contents for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive
Page 8: ...8 ...
Page 12: ...12 About this guide ...
Page 18: ...18 Specifications ...
Page 60: ...60 LCD panel and message descriptions ...
Page 96: ...96 Capacity expansion and extension ...
Page 102: ...102 Hard drive failures and faulted LUNs ...
Page 108: ...108 SCSI hard drive firmware ...