3.
While pressing the power supply module latch (
1
) to the left, grasp the module handle and pull the
defective power supply out of the chassis (
2
).
1
2
15494
Installing the component
1.
Slide the replacement power supply module into the MSA chassis bay until the module clicks into
place.
15495
2.
Connect the AC power cord to the power supply.
Verifying proper operation
After replacing the power supply, verify that:
•
The power supply Status LED is solid green.
•
No new error messages are displayed on the array controller LCD panel.
Replacing the MSA1500 chassis
In the event of a backplane board failure, a new chassis must be ordered. All original component parts
of the MSA can be reinstalled in their respective locations on the new backplane. The parts that will be
removed from the old chassis and then reinstalled in the new chassis include:
•
Controllers or blank
•
Hard drives or blanks
•
Power button module
•
Fibre Channel I/O modules or interconnect blank
•
Fan modules
•
SCSI I/O modules or blanks
•
Power supply modules
When
fi
nished, write the serial number of the original chassis on the label of the replacement chassis.
92
Customer replaceable components
Summary of Contents for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive
Page 8: ...8 ...
Page 12: ...12 About this guide ...
Page 18: ...18 Specifications ...
Page 60: ...60 LCD panel and message descriptions ...
Page 96: ...96 Capacity expansion and extension ...
Page 102: ...102 Hard drive failures and faulted LUNs ...
Page 108: ...108 SCSI hard drive firmware ...