Message
Type
Description
Action
112 VOLUME #<n>
REBUILD FAILURE
Error
The rebuild operation on
the con
fi
gured volume has
failed.
If the volume is still operating
in regenerative mode,
remove the new SCSI hard
drive that was added as a
replacement for the original
failed hard drive and replace
it with a different new drive.
113 VOLUME #<n>
EXPANSION FAILURE
Error
The volume expansion
operation on the con
fi
gured
volume has failed.
Open the Array
Con
fi
guration Utility (ACU)
or MSA Command Line
Interface (MSA-CLI) and use
it to determine the state of
the volume. If the volume is
still operational, it is possible
to retry the operation.
114 VOLUME #<n>
STATE DELETED
Informational
The con
fi
gured volume has
been deleted and is no
longer available. Volumes
are deleted by using the
Array Con
fi
guration Utility
(ACU) or MSA Command
Line Interface (MSA-CLI).
115 VOLUME #<n>
MEDIA EXCHANGED
Informational
All failed hard drives of the
speci
fi
ed volume have been
replaced by good hard
drives or all unplugged
hard drives in the volume
have been plugged back
in. This message should be
followed by message
02
ENABLE VOLUME <n>?
'<'=NO, '>'=YES
.
See the entry for
02 ENABLE
VOLUME <n>?
'<'=NO,
'>'=YES
.
120 CONFIGURED
VOLUMES <n>
Informational
The speci
fi
ed number of
con
fi
gured volumes was
detected at power-up.
121 NO VOLUMES
DETECTED
Informational
No con
fi
gured volumes
were detected at power-up.
If there are supposed to be
con
fi
gured volumes, power
off the MSA and then all
attached storage enclosures.
Unplug and reinsert all SCSI
hard drives ensuring they
are fully seated in their bays.
Check the cables connecting
the MSA to any attached
storage enclosures. Power
on the attached enclosures
and then the MSA.
122 NEW VOLUME(S)
DETECTED
Informational
Con
fi
gured volumes from
another array controller
were migrated to this
array controller. The
con
fi
guration information
has been updated.
maintenance and service guide
51
Summary of Contents for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive
Page 8: ...8 ...
Page 12: ...12 About this guide ...
Page 18: ...18 Specifications ...
Page 60: ...60 LCD panel and message descriptions ...
Page 96: ...96 Capacity expansion and extension ...
Page 102: ...102 Hard drive failures and faulted LUNs ...
Page 108: ...108 SCSI hard drive firmware ...