Message
Type
Description
Action
412 STORAGE BOX
#<n> EMU NOT
RESPONDING
Error
An EMU in the speci
fi
ed
storage enclosure is not
responding to commands.
Make sure the storage box
is powered on. Ensure
all cables are connected
securely. Power off the MSA
and the storage enclosure.
Then reapply power to the
storage box and then the
MSA.
Should the issue persist,
contact HP support.
413 STORAGE BOX
#<n> EMU VERSION
<version>
Informational
The version of
fi
rmware
running on the EMU. This
is only displayed for the
internal EMU of the MSA
chassis. It is not displayed
for externally connected
storage boxes.
414 STORAGE BOX
#<n> HOT REMOVED
Informational
An external storage
enclosure has been
hot-removed from the
back of the MSA.
415 STORAGE BOX
#<n> HOT ADDED
Informational
An external storage
enclosure has been
hot-added to the back
of the MSA.
450 INVALID SCSI
CABLING BOX #<n>
Error
The MSA has detected an
external storage enclosure
that is cabled incorrectly.
Verify that the external
storage enclosures are
connected properly to the
MSA. For more information,
see the MSA installation
guide.
500 INITIALIZING
PCI SUBSYSTEM
Informational
The array controller's
PCI subsystem is being
initialized as part of the
power-up sequence.
501 PCI SUBSYSTEM
HARDWARE FAILURE
Error
The array controller's PCI
subsystem has encountered
a critical error during the
power-up sequence.
Remove the failed array
controller, wait 10 seconds,
and then reinsert the array
controller, ensuring that it is
fully seated in the chassis.
Should the issue persist,
contact HP support.
502 PCI BRIDGE ASIC
SELF TEST FAILURE
Error
The array controller's
PCI bridge ASIC has
encountered a critical
error during the power-up
sequence.
Remove the failed array
controller, wait 10 seconds,
and then reinsert the array
controller, ensuring that it is
fully seated in the chassis.
Should the issue persist,
contact HP support.
510 INITIALIZING
FIBRE CHANNEL
SUBSYSTEM
Informational
The array controller's Fibre
Channel subsystem is being
initialized as part of the
power-up sequence.
maintenance and service guide
57
Summary of Contents for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive
Page 8: ...8 ...
Page 12: ...12 About this guide ...
Page 18: ...18 Specifications ...
Page 60: ...60 LCD panel and message descriptions ...
Page 96: ...96 Capacity expansion and extension ...
Page 102: ...102 Hard drive failures and faulted LUNs ...
Page 108: ...108 SCSI hard drive firmware ...