151 BEACON OFF
Informational
The LEDs on the MSA and
all connected hard drives
are no longer blinking
because the host-based
application is no longer
identifying or con
fi
guring
this MSA.
201 ARRAY
CONTROLLER
TEMPERATURE OK
Informational
The temperature sensor
on the array controller
indicates that the
temperature that was
previously exceeding the
normal operating range is
now back within the range.
202 ARRAY
CONTROLLER
OVERHEATING
Error
The temperature sensor
on the array controller
indicates that the array
controller is starting
to exceed the normal
operating range.
Check all MSA fans and
ensure they are operating.
Any failed fan should be
replaced. Ensure that there
is a module or blanking
panel (cover plate) in all
MSA chassis bays and slots.
Empty bays affect the air
fl
ow
and cooling ability of the
MSA.
203 ARRAY
CONTROLLER
OVERHEATED
Error
The temperature sensor
on the array controller
indicates that the array
controller has exceeded the
safe operating range.
The MSA should be powered
off as soon as possible to
avoid hardware failure.
Check all MSA fans and
ensure they are operating.
Any failed fan should be
replaced. Ensure that there
is a module or blanking
panel (cover plate) in all
MSA chassis bays and slots.
Empty bays affect the air
fl
ow
and cooling ability of the
MSA.
204 ARRAY
CONTROLLER DISABLED
Error
The array controller has
been disabled due to a
redundancy failure.
Remove the failed array
controller, wait 10 seconds,
and then reinsert the array
controller, ensuring that it is
fully seated in the chassis.
Should the issue persist,
contact HP support.
205 ARRAY
CONTROLLER
RESTARTING
Informational
The array controller has
completed
fi
rmware cloning
and will be restarted
automatically.
300 RECOVERY ROM
AUTOFLASH STARTED
Informational
The array controller has
detected that the
fi
rmware's
backup recovery ROM
image is invalid and is
copying the current active
fi
rmware image into the
backup recovery ROM.
maintenance and service guide
53
Summary of Contents for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive
Page 8: ...8 ...
Page 12: ...12 About this guide ...
Page 18: ...18 Specifications ...
Page 60: ...60 LCD panel and message descriptions ...
Page 96: ...96 Capacity expansion and extension ...
Page 102: ...102 Hard drive failures and faulted LUNs ...
Page 108: ...108 SCSI hard drive firmware ...