Message
Type
Description
Action
511 FIBRE CHANNEL
SUBSYSTEM HARDWARE
FAILURE
Error
The array controller's Fibre
Channel subsystem has
encountered a critical
error during the power up
sequence.
Remove the failed array
controller and its associated
Fibre Channel module,
reseat the Fibre Channel
daughter card on the array
controller, wait 10 seconds,
then reinsert the Fibre
Channel module and the
array controller, ensuring
that they are fully seated in
their respective bays in the
chassis.
Should the issue persist,
contact HP support.
513 UNCORRECTED ECC
MEMORY ERROR SEEN
Error
The array controller has
detected an uncorrectable
error in the ECC memory on
the memory cache board.
Remove the failed array
controller and replace the
memory cache board with a
new one.
514 FIBRE SWITCH
HARDWARE FAILURE
Error
The embedded switch in the
Fibre Channel I/O bay is
not responding correctly or
is not working. (Please note
that some switches take
several minutes to start up.)
Remove the embedded
switch, wait 10 seconds,
and then reinsert the switch,
ensuring that it is fully seated
in the chassis.
Should the issue persist,
contact HP support.
515 FIBRE DEVICE
HARDWARE FAILURE
Error
The array controller
fi
rmware does not
recognize the device in
the Fibre Channel I/O bay.
The device has failed or
is not supported by the
installed
fi
rmware version.
If the device was not recently
installed or the
fi
rmware was
not recently downgraded,
remove the embedded
device, wait 10 seconds,
and then reinsert the device,
ensuring that it is fully seated
in the chassis.
Should the issue persist,
contact HP support.
516 FIBRE SUBSYSTEM
LINK FAILURE
Error
The controller is not currently
linked to anything. This
could be due to the
following:
•
The Fibre Channel cable
is not connected.
•
The device to which it
is connected is currently
not working.
•
The MSA is connected
to a device that with an
incompatible port type.
Check the connections
on both ends of the Fibre
Channel cables and make
sure that the switch, hub, or
other system that the
fi
bre is
connected to is operating
properly and is properly
con
fi
gured.
Should the issue persist,
contact HP support.
517 FIBRE SUBSYSTEM
LINK OK
Informational
The Fibre Channel port has
transitioned to an online
state.
58
LCD panel and message descriptions
Summary of Contents for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive
Page 8: ...8 ...
Page 12: ...12 About this guide ...
Page 18: ...18 Specifications ...
Page 60: ...60 LCD panel and message descriptions ...
Page 96: ...96 Capacity expansion and extension ...
Page 102: ...102 Hard drive failures and faulted LUNs ...
Page 108: ...108 SCSI hard drive firmware ...