Message
Type
Description
Action
67 CACHE HARDWARE
TEMPORARILY
DISABLED
Informational
The cache memory
hardware has temporarily
been disabled, typically
because the battery is not
charged or a capacity
expansion operation is
occurring. The cache
automatically enabled once
the condition has been
corrected.
68 OBSOLETE CACHE
DATA DELETED
Informational
Old data that no longer
belongs to any current
con
fi
gured volumes was
found in the cache memory
at power up. This data has
been deleted. This typically
happens if cache modules
are moved between array
controllers.
69 CACHE BATTERIES
LOW, RECHARGING
Informational
The batteries on the cache
module are low and are
being recharged.
70 CACHE DISABLED
NO CONFIGURATION
Informational
The cache has not
been con
fi
gured and is
disabled. The cache is
con
fi
gured using the Array
Con
fi
guration Utility (ACU)
or MSA Command Line
Interface (MSA-CLI).
71 SYSTEM HALTED
FOR CACHE ERROR
Error
This message is displayed
upon a
no
response
to message
72 CACHE
ERROR <n> IGNORE?
<=NO >=YES
.
See the information for
message
72 CACHE
ERROR
.
46
LCD panel and message descriptions
Summary of Contents for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive
Page 8: ...8 ...
Page 12: ...12 About this guide ...
Page 18: ...18 Specifications ...
Page 60: ...60 LCD panel and message descriptions ...
Page 96: ...96 Capacity expansion and extension ...
Page 102: ...102 Hard drive failures and faulted LUNs ...
Page 108: ...108 SCSI hard drive firmware ...