CAUTION:
Use appropriate precautions when handling Fibre Channel cables:
•
Touching the end of a Fibre Channel cable will either damage the cable or cause performance
problems, including intermittent dif
fi
culties accessing the storage.
•
Whenever a Fibre Channel cable is not connected, replace the protective covers on the ends of
the cable.
•
Make certain that the Fibre Channel cables are installed and supported so that no excess weight is
placed on the connectors. This prevents damage to the connector and cable. Excess cable should
be loosely coiled and tied out of the way, being careful not to coil the cable in a tight loop with a
bend radius of less than 3 inches (7.62 cm).
1.
Review all warnings, cautions, and preparation procedures as detailed in
Warnings and precautions
.
2.
Disconnect the cable from the Fibre Channel I/O module.
3.
Lift the port-colored Fibre Channel I/O module latch (
1
) and pull the Fibre Channel I/O module
out of the chassis (
2
).
2
1
15498
Installing the component
1.
Slide the replacement Fibre Channel I/O module into the MSA chassis bay until the module clicks
into place.
15502
2.
Either move the SFP transceiver from the old Fibre Channel I/O module or install a new SFP
transceiver in the new module. For instructions on removing and installing an SFP, see
Replacing a
2-Gb small form factor pluggable (SFP) transceiver
.
3.
Reconnect the cables.
86
Customer replaceable components
Summary of Contents for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive
Page 8: ...8 ...
Page 12: ...12 About this guide ...
Page 18: ...18 Specifications ...
Page 60: ...60 LCD panel and message descriptions ...
Page 96: ...96 Capacity expansion and extension ...
Page 102: ...102 Hard drive failures and faulted LUNs ...
Page 108: ...108 SCSI hard drive firmware ...