15497
2.
Reconnect all SCSI cables.
NOTE:
Ensure that all of the SCSI cable connectors are fastened tightly.
Verifying proper operation
After replacing the failed SCSI I/O module, verify that:
•
The SCSI I/O module Status LED is solid green.
•
No new error messages are displayed on the array controller LCD panel.
Replacing a power supply module
The power supply is hot-pluggable, so it is not necessary to power down the system to replace it.
Before you begin
CAUTION:
•
Before removing a component or blanking panel from an operational device, make sure that you
have the replacement part available. Removing a component or blank impacts the air
fl
ow and
cooling ability of the device. To avoid possible overheating, insert the new or replacement component
within one or two minutes. If the internal temperature exceeds acceptable limits, the device may
overheat and automatically shut down or restart.
•
Parts can be damaged by electrostatic discharge. Use proper anti-static protection.
Verifying component failure
•
Check the array controller LCD display panel for error messages.
•
Verify that the electrical source is delivering power down the AC power cord.
•
Verify that the power supply fault LED is blinking amber.
•
Verify that the power supply Status LED is Off.
Removing the component
1.
Review all warnings, cautions, and preparation procedures as detailed in
Warnings and precautions
.
2.
Disconnect the AC power cord from the failed power supply.
maintenance and service guide
91
Summary of Contents for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive
Page 8: ...8 ...
Page 12: ...12 About this guide ...
Page 18: ...18 Specifications ...
Page 60: ...60 LCD panel and message descriptions ...
Page 96: ...96 Capacity expansion and extension ...
Page 102: ...102 Hard drive failures and faulted LUNs ...
Page 108: ...108 SCSI hard drive firmware ...