User input messages
User input messages indicate that the system has encountered a situation that allows user input. The user
can select from a number of choices. If the user does not select one of the choices in a set amount of
time, the system selects the default setting. These user input messages only occur during system power
on, and not during runtime.
The array controller Fault LED to the left of the LCD panel display window blinks on and off when a user
input message is currently being viewed and is available for input. If input is not provided within the
time-out period, the message remains but the LED stops blinking.
LCD message descriptions
The following table describes the MSA LCD messages.
Table 2 LCD panel messages
Message
Type
Description
Action
00 ARRAY CONTROLLER
FIRMWARE VER
<version>
Informational
Displays the current version
of
fi
rmware running on the
MSA array controller.
01 STARTUP COMPLETE
Informational
The array controller has
completed its power-on
sequence and is now
operational.
02 ENABLE VOLUME
<n>?
'<'=NO,
'>'=YES
User input
An issue has been found
with a con
fi
gured volume
that may result in data loss,
so the volume has been
disabled. The exact nature
of the issue is detailed in
a previous LCD display
message.
Yes
= the volume is enabled
(regardless of the issue.) The
volume attempts to return to
its normal operating state
and the data is accessible.
No
= not selecting any
option within the time-out
period = the volume remains
disabled. The volume stays
in the failed state and the
data is not be accessible.
During this time, the user can
attempt to
fi
x the issue.
no input =
No
03 CRITICAL LOCK-UP
DETECTED. CODE=<n>
Error
A critical error has been
detected by the array
controller
fi
rmware. To
prevent any possible
data loss, the
fi
rmware
has entered a lock-up
state. The provided code
contains engineering
speci
fi
c information about
the lock-up condition.
In dual-controller
con
fi
gurations where only
one controller is locked-up,
remove the array controller in
question, wait 10 seconds,
and then reinsert it ensuring
that it is fully seated in the
chassis.
In single-controller
con
fi
gurations and in
dual-controller con
fi
gurations
where both controllers are
locked-up, restart the MSA
chassis.
Should the issue persist,
contact HP support.
maintenance and service guide
37
Summary of Contents for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive
Page 8: ...8 ...
Page 12: ...12 About this guide ...
Page 18: ...18 Specifications ...
Page 60: ...60 LCD panel and message descriptions ...
Page 96: ...96 Capacity expansion and extension ...
Page 102: ...102 Hard drive failures and faulted LUNs ...
Page 108: ...108 SCSI hard drive firmware ...