Verifying component failure
Before replacing the controller, cache module, or battery pack:
•
Check the controller LCD display panel for error messages.
•
Record any failure LEDs or LCD panel messages for reference purposes.
•
Check the controller heartbeat LED (
1
) . If the LED is not blinking, it might indicate a failure.
•
Check the controller fault LED (
2
) . If the LED is on, it might indicate a failure.
1
2
15512
Removing the controller
1.
Review all warnings, cautions, and preparation procedures as detailed in
Warnings and precautions
.
2.
Review all controller-speci
fi
c warnings, cautions, and preparation procedures as detailed in
Before
you begin
.
3.
In all single-controller con
fi
gurations, power off the MSA as instructed in
Removing power from
the MSA
.
4.
In operational dual-controller con
fi
gurations, access an MSA management utility, such as the
MSA Command Line Interface (MSA-CLI) or the Array Con
fi
guration Utility (ACU) and disable the
controller being removed. For instructions, see online help. (During this procedure, because one of
the two controllers is being removed, the MSA operates in a non-redundant mode.)
5.
Press the controller thumb latch and rotate the latch handle out (
1
).
6.
Pull the controller straight out of the chassis (
2
).
2
1
15492
maintenance and service guide
79
Summary of Contents for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive
Page 8: ...8 ...
Page 12: ...12 About this guide ...
Page 18: ...18 Specifications ...
Page 60: ...60 LCD panel and message descriptions ...
Page 96: ...96 Capacity expansion and extension ...
Page 102: ...102 Hard drive failures and faulted LUNs ...
Page 108: ...108 SCSI hard drive firmware ...