15621
1
2
3.
Close the ejector lever against the front of the hard drive (
2
).
4.
Verify that the hard drive is
fi
rmly engaged and that the ejector lever is latched.
CAUTION:
Data can be lost if the hard drive is not
fi
rmly seated.
5.
As the hard drive begins to spin, the drive LEDs will illuminate, indicating that the system has
recognized the new drive. In fault-tolerant con
fi
gurations, allow the replacement hard drive to
be reconstructed automatically from parity data stored on the other hard drives. While the data
is being rebuilt, the LEDs will
fl
ash.
Verifying proper operation
The hard drive LEDs light one at a time and then turn off together to indicate that the system has
recognized the new drive. In fault tolerant con
fi
gurations, allow the replacement hard drive to be
reconstructed automatically with data from the other hard drives. While reconstruction is in progress,
the online LEDs
fl
ash.
maintenance and service guide
77
Summary of Contents for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive
Page 8: ...8 ...
Page 12: ...12 About this guide ...
Page 18: ...18 Specifications ...
Page 60: ...60 LCD panel and message descriptions ...
Page 96: ...96 Capacity expansion and extension ...
Page 102: ...102 Hard drive failures and faulted LUNs ...
Page 108: ...108 SCSI hard drive firmware ...