15517
5.
Lift the pack upward to unhook the top of the battery pack.
15518
6.
Wait approximately 15 seconds after removing the old battery to allow the battery charge monitor
to reset.
NOTE:
If you do not wait 15 seconds after removing the old battery, full charge of the new cache
battery is delayed.
7.
Repeat
step 3
through
step 6
to remove the second battery pack on this cache module.
Installing the controller cache battery pack
1.
Remove the array controller as instructed in
Removing the controller
.
2.
Remove the controller cache module as instructed in
Removing the controller cache module
.
3.
Remove the controller cache battery pack as instructed in
Removing the controller cache battery pack
.
4.
Hook the top of the new NiMH battery pack to the top of the module, with the pack held at a
30-degree angle to the plane of the module.
15519
82
Customer replaceable components