![horiba HU-200TB SS-120 Instruction Manual Download Page 46](http://html1.mh-extra.com/html/horiba/hu-200tb-ss-120/hu-200tb-ss-120_instruction-manual_2162225046.webp)
Measurement
38
Set whether or
not an automatic
cleaner will be
used
"no"
"yES"
"no"
When the cleaner is detached, set the
use of the automatic cleaner to "no".
Set the use of the automatic cleaner
to "yES".
Selecting "yES" will check the
connection of the cleaner.
Set a cleaning
operation type
(when the use of
an automatic
cleaner is set to
"yES")
"nor"
"or"
"And"
"trg"
or
Select a combinational operation
between the internal timer and the
external directive for cleaning.
z
"nor": This is the normal setting.
The cleaner does not accept an
external directive, and only
performs the cleaning in response
to the cleaning cycle defined by
the internal timer. However, a
transmission signal is held by an
external directive.
z
"or": The cleaner operates in
response to the internal timer, and
performs the cleaning only while
an internal directive is input.
z
"And": The cleaner performs the
cleaning in response to the internal
timer only while an external
directive is input.
z
"trg": This disables the capabilities
of the internal timer. The cleaner
performs the cleaning only in
response to an external directive
(trigger for two s or longer).
See “ Cleaning operation ” (page 48).
ISet a cleaning
cycle for the
internal timer
(when the use of
an automatic
cleaner is set to
"yES")
0.1 to 168.0 h
3
Define a cleaning cycle in units of
hours.
(when the cleaning operation type is
set to "Nor", "Or" or "And")
Cleaning time setting
Set cleaning time
(when the use of
an automatic
cleaner is set to
"yES")
20 to 600 s
20
Define the cleaning time in units of
seconds.
Set the extended
time for
transmission
output hold after
the end of
cleaning
60 to 600 s
120
Define the time to be held after the
end of cleaning.
Note: If cleaning output to set to "no",
the output after the release of test
cleaning is held.
Set RS-485
address
0 to 99
0
Specify an address for RS-485
communication.
Screen 1
Screen 2
Description
Setting range
Initial
value
Remarks