Section 5 – Programming
5–31
Table 5–11: Line Device Menu Options (cont’d)
Select
Device
Type
Line
Device
Menu
Choice Choice Choice Choice Default Comments
Caller ID
Yes
✔
No
Caller ID to
Automation: When
enabled, Caller ID
information is output to
the automation system
only in the event that
no alarm data is
received from a
security system control
panel.
Caller ID to Printer
Ports: When enabled,
Caller ID information is
output to the printer
port(s) for every call
received at the time
that the Caller ID
information is available
from the Public
Switched Telephone
Network (normally
between the first and
second ring.) This
option should only be
used when connected
to a parallel or serial
printer or equivalent.
Y (Yes)
Initiates a 2-second
delay at the start of
each call before the
handshake delay.
Billing Delay
N (No)
✔
See page 5–47 for
more information.
Hunt Group
00-99
00
Allows multiple line
cards to report under
the same group
number to the
automation software.
Min Ring (15-
99)
40
Max Ring
(015-100)
060
Ring Off
(1500-8000)
4000
Min Ring Off
(100-800)
450
Ring Error
(0800-4400)
2200
Ring
Options
Min # Ring
Periods (01-
20)
05
See page 5–48 for
more information.
MX8000–
LC3
3 Line
(cont’d)
Edit Line
(cont’d)
Line #
(cont’d)
Misc. Line
Options
(cont’d)
Call Hang-
up
60-180 sec
120 sec
Sets the maximum
amount of time that a
call can last before the
receiver hangs up on
the call if an event is
not in progress. See
page 5–49 for details.