Section 5 – Programming
5–23
5.4.4.2 How to Set the Receiver as a Single, Slave, or Master
In large central stations, it may be desired to set up receivers in a master/slave relationship for reporting to
a printer. To set the receiver to act as a single receiver, master receiver, or slave receiver, proceed as follows:
1. Enter program mode. (See Section 5.1.)
2. Press
1
for general options.
3. Press
4
for system options.
4. Press
.
The display will flash on the receiver mode:
Single
5. Press
the
or
button until the display flashes on the desired setting.
6. Press
ENTER
MENU
.
To Exit:
Press
until you return to the main menu.
5.4.4.3 How to Set the Receiver ID Number
In large central stations where calls may be coming in on several receivers at once, the automation software
will need to identify which receiver it received a call from. This will help in troubleshooting if a problem
occurred with the automation system or receiver.
1. Enter program mode. (See Section 5.1.)
2. Press
1
for general options.
3. Press
4
for system options.
4. Press
.
The display will flash on the receiver ID number:
Rcvr ID=
01
5. Enter the desired receiver ID number (a number from 01 to 99).
Note:
If you are outputting to an automation computer using 685, CAPS, or CP-220 automation protocol,
see Table 5–10 for valid entries for ID numbers 1–9 and A–Z.
6. Press
ENTER
MENU
.
To Exit:
Press
until you return to the main menu.
Table 5–10: 685, CAPS, and CP-220 1–9/A–Z Entries
Keypad
Entry
Number/
Letter
Keypad
Entry
Number/
Letter
Keypad
Entry
Number/
Letter
Keypad
Entry
Number/
Letter
01 1
65 A 74 J
83 S
02 2
66 B 75 K 84 T
03 3
67 C 76 L 85 U
04 4
68 D 77 M 86 V
05 5
69 E 78 N 87 W
06 6
70 F 79 O 88 X
07 7
71 G 80 P 89 Y
08 8
72 H 81 Q 90 Z
09 9
73 I
82 R