Performing CCI Operations
1–47
Hitachi AMS 2000 Family Command Control Interface (CCI) Reference Guide
•
• NG: The horctakeover command is rejected, and the operation
terminates abnormally.
• Nop-Takeover: The horctakeover command is accepted, but no
operation is performed.
• Volumes not conform: The volumes are not in sync, and the
horctakeover command terminates abnormally.
• Unknown: The remote node attribute is unknown and cannot be
identified. The remote node system is down or cannot communicate.
• SSWS: Suspend for Swapping with S-VOL side only. The SSWS state is
displayed as SSUS (SVOL_PSUS) by ALL commands except the -fc
option of the pairdisplay command.
When the attribute of the self-node volume is SSUS, the target displays the
NG message but the status changes to SSWS.
Table 1-17: Volume Attributes and Takeover Actions (TCE)
Local Node (Takeover Node)
Remote Node
Volume
Attribute
Fence Level and
Status
Volume
Attribute
P-VOL
Status
Takeover Action
SMPL
-
SMPL
-
NG
[1]
P-VOL
-
Nop-Takeover
[2]
S-VOL
-
Volumes not conform
[3]
Unknown
[4]
-
NG
P-VOL
(primary)
Fence = Async
SMPL
-
NG
P-VOL
-
Volumes not conform
S-VOL
-
Nop-Takeover
Unknown
-
Nop-Takeover
S-VOL
(secondary)
Fence = Async
and
Status = SSWS
-
-
Nop-Takeover
Fence = Async
and
Status = PSUS(N)
-
-
NG
Fence = Async
and
Status = COPY
-
-
NG
Others
SMPL
-
Volumes not conform
P-VOL
PAIR
SVOL-Takeover
Others
SVOL-Takeover Note 2
S-VOL
-
Volumes not conform
Unknown
-
SVOL-Takeover Note 2