3–16
Maintenance log and tracing functions
Hitachi AMS 2000 Family Command Control Interface (CCI) Reference Guide
9576
007C
84
Management information of
Dynamic Provisioning is being
updated.
Retry after waiting for a
while.
9576
007D
84
The operation cannot be
performed due to insufficient
capacity of the DP pool for the
specified P-VOL.
Check the capacity of the DP
pool.
9576
007E
84
The operation cannot be
performed due to insufficient
capacity of the DP pool for the
specified S-VOL.
Check the capacity of the DP
pool.
9576
007F
84
The memory reconfiguration
process is in progress.
Retry after the memory
reconfiguration process
completes.
9576
0080
84
The memory reconfiguration
process is in progress.
Retry after the memory
reconfiguration process
completes.
9576
0081
84
The status of the specified S-VOL
is SMPL, COPY, or PAIR.
Check the pair status.
9576
0082
84
There are no pairs in the specified
group whose status is SSWS.
Check the pair status.
9576
905E
94
There is a SnapShot pair, which
has an MU number specified for a
SnapShot P-VOL, has not been
placed in the PAIR or PSUS status,
and whose S-VOL is one of the S-
VOLs with the specified CTG
numbers. Otherwise, the process
of reconfigure memory is in
progress on the remote array.
Check the pair status of the
SnapShot. Otherwise, retry
after the process of
reconfigure memory is
completed.
9576
905F
94
There is no pair, which is in the
PAIR status, in the target CTG.
Check the pair status of the
LU.
9576
x005
94
The LU of the remote array is
being formatted.
Retry after waiting for a
while.
9576
x006
94
The remote array is undergoing
the pseudo deliberate shutdown.
Retry after the pseudo
deliberate shutdown is
completed.
9576
x007
94
The remote array has undergone
the pseudo deliberate shutdown.
Retry after waiting for a
while.
9576
x008
94
The S-VOL is undefined.
Check the status of the LU.
9576
x009
94
The WWN of the remote array is
illegal.
Check the array WWN.
9576
x00B
94
The remote array is undergoing
hot replacement of the firmware.
Retry after waiting for a
while.
9576
x00C
94
A command error occurred.
Retry after waiting for a
while.
9576
x00D
94
The optional feature of TrueCopy
of the remote array is invalid.
Unlock and validate the
optional feature.
Table 3-5: Sense Codes (Continued)
Sense
code
Detailed
code
Sub
code
Error contents
Recommended Action
Summary of Contents for AMS 2000 Series
Page 6: ...vi Table of Contents Hitachi AMS 2000 Family Command Control Interface CCI Reference Guide ...
Page 244: ...4 18 Command options Hitachi AMS 2000 Family Command Control Interface CCI Reference Guide ...
Page 261: ...1 Hitachi AMS 2000 Family Command Control Interface CCI Reference Guide ...