3–60
Maintenance log and tracing functions
Hitachi AMS 2000 Family Command Control Interface (CCI) Reference Guide
9622
007E
84
The pool LU is undergoing the
forced parity correction.
Retry after waiting for a
while.
9622
007F
84
There is one or more P-VOLs, the
status of the forced parity
correction for which is Uncorrected
or Uncorrected 2, in the target
CTG.
Check the status of each LU
in the target CTG.
9622
0080
84
There is one or more P-VOLs,
status is normal or other than
regressed, in the target CTG
Check the status of each LU
in the target CTG.
9622
0081
84
There is one or more TCE P-VOLs,
which is cascaded with a SnapShot
P-VOL being restored, in the target
CTG.
Check the status of each LU
in the target CTG.
9622
0082
84
There is one or more TCE P-VOLs,
which is cascaded with a SnapShot
P-VOL that was placed in the PSUE
status during restoration, in the
target CTG.
Check the status of each LU
in the target CTG.
9622
0083
84
There is no pair, which is in the
PSUS or PSUE status, in the target
CTG.
Check the pair status of each
LU in the target CTG.
9622
0084
84
When a pair is created in the new
CTG, the cycle time that has been
set is less than “30 x number of
CTGs” seconds.
Check the cycle time that has
been set.
9622
0085
84
When the unit of pair is specified,
the S-VOL of the target pair has
not completed the
resynchronization after it accepted
the resync command.
Check the TCE pair status of
the remote array.
9622
0086
84
When the unit of CTG is specified,
there is one or more S-VOLs,
which has not completed the
resynchronization after it accepted
the resync command, in the target
CTG.
Check the TCE pair status of
the remote array.
9622
0087
84
There are one or more pairs in the
status of “under pair splitting” or
“under pair competing” in the
CTG.
Retry after waiting for a
while.
9622
0088
84
The specified P-VOL is the
reserved LU.
Check the status of the LU.
9622
0089
84
The specified P-VOL is undergoing
the migration.
Check the pair status of the
LU.
9622
008A
84
The disk drives that configure a
RAID group, to which the specified
P-VOL belongs have been spun
down.
Check the status of the RAID
group.
Table 3-5: Sense Codes (Continued)
Sense
code
Detailed
code
Sub
code
Error contents
Recommended Action
Summary of Contents for AMS 2000 Series
Page 6: ...vi Table of Contents Hitachi AMS 2000 Family Command Control Interface CCI Reference Guide ...
Page 244: ...4 18 Command options Hitachi AMS 2000 Family Command Control Interface CCI Reference Guide ...
Page 261: ...1 Hitachi AMS 2000 Family Command Control Interface CCI Reference Guide ...