9622
0038
84
There is no vacancy in the
generation bits.
Retry after waiting for a
while.
9622
0039
84
There is one or more pairs in the
status of “under execution of
pairsplit -mscas command” in the
target CTG.
Check the pair status of each
LU in the target CTG. It is
required to wait until the
process is completed.
9622
003A
84
There is one or more pairs in the
status of “under pair splitting” in
the target CTG.
Check the pair status of each
LU in the target CTG. It is
required to wait until the
process is completed.
9622
003C
84
There is one or more pairs in the
status of “under pair deletion” in
the target CTG.
Check the pair status of each
LU in the target CTG. It is
required to wait until the
process is completed.
9622
003D
84
The specified P-VOL is a SnapShot
P-VOL and it is being restored.
Check the pair status of the
SnapShot.
9622
003E
84
The specified P-VOL is a SnapShot
P-VOL and its status was changed
to PSUE during restoration.
Check the pair status of the
SnapShot.
9622
003F
84
There is no pair, which is in the
PAIR status, in the target CTG.
Check the pair status of each
LU in the target CTG.
9622
0042
84
When the unit of pair is specified,
the pair status of the specified pair
is PSUS (no reading or writing
allowed).
Check the pair status.
9622
0044
84
When the unit of CTG is specified,
there is one or more pairs placed
in the PSUS status (no reading or
writing allowed) in the CTG.
Check the pair status of each
LU in the target CTG.
9622
0045
84
When the unit of CTG is specified,
there is no pair that is in the PAIR,
PSUS, or PSUE status in the CTG.
Check the pair status of each
LU in the target CTG.
9622
0046
84
When the unit of CTG is specified,
the internal status of the pair of
the specified P-VOL is “under pair
splitting”.
Check the pair status of the
LU. It is required to wait until
the process is completed.
9622
0047
84
The specified P-VOL has the
incomplete DDCB.
Check the status of the LU.
9622
0048
84
The specified P-VOL has unwritten
data.
Contact the service
personnel.
9622
0049
84
When the unit of pair is specified,
the internal status of the pair of
the specified P-VOL is “under pair
deletion”.
Check the pair status of the
LU. It is required to wait until
the process is completed.
9622
004B
84
When the unit of pair is specified,
the internal status of the pair of
the specified P-VOL is “under
execution of the pairsplit -mscas
command”.
Check the pair status of the
LU. It is required to wait until
the process is completed.
Table 3-5: Sense Codes (Continued)
Sense
code
Detailed
code
Sub
code
Error contents
Recommended Action
Summary of Contents for AMS 2000 Series
Page 6: ...vi Table of Contents Hitachi AMS 2000 Family Command Control Interface CCI Reference Guide ...
Page 244: ...4 18 Command options Hitachi AMS 2000 Family Command Control Interface CCI Reference Guide ...
Page 261: ...1 Hitachi AMS 2000 Family Command Control Interface CCI Reference Guide ...