![Hitachi AMS 2000 Series Reference Manual Download Page 121](http://html.mh-extra.com/html/hitachi/ams-2000-series/ams-2000-series_reference-manual_146092121.webp)
Performing CCI Operations
1–103
Hitachi AMS 2000 Family Command Control Interface (CCI) Reference Guide
•
•
Figure 1-83: Pairsyncwait Command Examples
Time
1
2
3
4
5
Write
Differential data determined
P-VOL
S-VOL
Differential data transmitted
Cycle time
Issue the pairsyncwait command
Get the sequence number (0100340211)
Internally determined data
p
y
Since the reflection on the remote S-VOL has been done up to the
sequence number (0100340212), a response is returned to the
pairsyncwait command.
T0
T1
T2
When the command is -nowait, the sequence number (0100340211)
is returned immediately after the command is issued.
Write Sequence
number
1 0100340210
2 0100340211
3 0100340212
4 0100340213
5 0100340214
Write
Differential data determined
Write
Write
Write
P-VOL
4
5
1
2
3
1
2
3
# pairsyncwait –g oradb -nowait
-nowait is specified.
UnitID CTGID Q-Marker Status Q-Num
0 3
01003408ef
NOWAIT 2
# pairsyncwait –g oradb -t 100
-nowait is not specified.
UnitID CTGID Q-Marker Status Q-Num
0 3 01003408ef DONE 2
# pairsyncwait –g oradb -t 1
UnitID CTGID Q-Marker Status Q-Num
0 3
01003408ef
TIMEOUT 3
# pairsyncwait –g oradb -t 100 –m
01003408ef
UnitID CTGID Q-Marker Status Q-Num
0 3 01003408ef DONE 0
# pairsyncwait –g oradb -t 100
UnitID CTGID Q-Marker Status Q-Num
0 3 01003408ef BROKEN 0
# pairsyncwait –g oradb -t 100 -m
01003408ef
UnitID CTGID Q-Marker Status Q-Num
0 3 01003408ef
CHANGED
0
Q Marker(01003408ef) is invalid when P-VOL was
resynchronized while this command is executed.