Maintenance log and tracing functions
3–13
Hitachi AMS 2000 Family Command Control Interface (CCI) Reference Guide
9576
0046
84
The specified LU is a V-VOL of
SnapShot. The
P-VOL of the related SnapShot pair
is a unified LU, whose MainLU and
SubLU are different in number of
data disks.
Check that the number of
data disks of the SnapShot P-
VOL corresponding to the
specified LU is the same as
that expected.
9576
0047
84
Data of the TrueCopy P-VOL is
partially destroyed.
Issue the Snapshot
instruction (to change the
status from PAIR to PSUS) to
the SnapShot pair again, and
then create the pair again.
9576
0048
84
Data of the TrueCopy P-VOL is
partially destroyed.
Format the specified LU after
getting backup data of it.
Then restore the backup
data.
9576
0049
84
A problem occurred in the pair.
After splitting the pair, create
a pair again.
9576
004A
84
A problem occurred in the pair.
After splitting the pair, create
a pair again.
9576
004B
84
The specified P-VOL is in the PSUE
(S-VOL Switch) status of
ShadowImage.
Request the service
personnel to replace drives
that compose the P-VOL.
Format them after the
replacement, and then
resynchronize them.
9576
004D
84
The DM-LU is not set.
Retry after setting the DM-
LU.
9576
004E
84
The DM-LU cannot be specified as
P-VOL.
Check the status of the LU.
9576
004F
84
Validity of the license expired.
Purchase the license.
9576
0052
84
The pairsplit -mscas was issued in
the TrueCopy environment.
The pairsplit -mscas is not
supported in the TrueCopy
environment.
9576
0053
84
The specified P-VOL is the
reserved LU.
Check the status of the LU.
9576
0054
84
The specified P-VOL is undergoing
the migration.
Check the pair status of the
LU.
9576
0055
84
The disk drives that configure a
RAID group, to which the specified
P-VOL belongs have been spun
down.
Check the status of the RAID
group.
9576
0056
84
The disk drives that configure a
RAID group, to which the specified
P-VOL belongs have been spun
down.
Check the status of the RAID
group.
9576
0057
84
The specified function is not
supported in a remote array.
Check the remote array.
9576
0058
84
When creating pairs with CTG is
specified, the specified CTG ID is
beyond the limits of supported.
Check the specified CTG ID.
Table 3-5: Sense Codes (Continued)
Sense
code
Detailed
code
Sub
code
Error contents
Recommended Action
Summary of Contents for AMS 2000 Series
Page 6: ...vi Table of Contents Hitachi AMS 2000 Family Command Control Interface CCI Reference Guide ...
Page 244: ...4 18 Command options Hitachi AMS 2000 Family Command Control Interface CCI Reference Guide ...
Page 261: ...1 Hitachi AMS 2000 Family Command Control Interface CCI Reference Guide ...