HYBRID/TROUBLE SHOOTING
3–654
1.
Remove the SMR#1 from the high-voltage J/B (in the battery
pack).
2.
Using the electrical tester, measure the resistance between the
SMR#1 terminals.
NO
YES
1.
Remove the SMR#2 from the high-voltage J/B (in the battery
pack).
2.
Using the electrical tester, measure the resistance between the
SMR#2 terminals.
NO
YES
11
Inspecting the SMR#1
SHTS03ZZZ0300427
Measurement
conditions
Tester
connections
Standard values
—
SMR#1
1st terminal
–
2nd terminal
70
–
190
Is the measured value within the range of standard value?
Go to step 12.
Replace the SMR#1.
After replacement, go to step 12.
12
Inspecting the SMR#2
SHTS03ZZZ0300428
Measurement
conditions
Tester
connections
Standard values
—
SMR#2
1st terminal
–
2nd terminal
19
–
50
Is the measured value within the range of standard value?
Go to step 13.
Replace the SMR#2.
After replacement, go to step 13.