HYBRID/TROUBLE SHOOTING
3–577
1.
Set the starter key to the "LOCK" position.
2.
Remove the inverter start relay.
3.
Using the electrical tester, measure the resistance between the
terminals of PCU harness (24P) connector and inverter start relay
connector (relay block side).
NO
YES
1.
Using the electrical tester, measure the resistance between the
3rd terminal of inverter start relay connector (relay block side) and
the ground.
NO
YES
5
Inspecting the PCU wire harness (lower side) for continuity 1
SHTS03ZZZ0300373
Measurement
conditions
Tester
connections
Standard values
Starter key: LOCK
PCU harness (24P)
lower-side con-
nector
–
Inverter
start relay connec-
tor (relay block
side)
3rd terminal
–
3rd terminal
1
or less
(With continuity)
Is the measured value within the range of standard value?
Go to step 6.
Replace the PCU wire harness (lower side).
6
Inspecting the PCU wire harness (lower side) for short circuit 1
Vehicle GND
SHTS03ZZZ0300374
Measurement
conditions
Tester
connections
Standard values
Starter key: LOCK
Inverter start relay
connector (relay
block side)
3rd terminal
–
GND
10 k
or more
(No continuity)
Is the measured value within the range of standard value?
Go to step 7.
Replace the PCU wire harness (lower side).