HYBRID/TROUBLE SHOOTING
3–682
1.
Remove the SMR#3 from the high-voltage J/B (in the battery
pack).
2.
Using the electrical tester, measure the resistance between the
SMR#3 terminals.
NO
YES
1.
Remove SMR#1 or SMR#3 from the high-voltage J/B (in the bat-
tery pack).
2.
Using the electrical tester, measure the resistance between the
terminals of high-voltage J/B (in the battery pack).
NO
YES
5
Inspecting the SMR#3
SHTS03ZZZ0300448
Measurement
conditions
Tester
connections
Standard values
—
SMR#3 terminal
(switch side)
3rd terminal
–
5th terminal
10 k
or more
(No continuity)
Is the measured value within the range of standard value?
Go to step 6.
Replace the SMR#3.
After replacement, go to step 6.
6
Inspecting the high-voltage J/B (in the battery pack)
BATT OUT(-)
BATT IN(-)
SHTS03ZZZ0300449
Measurement
conditions
Tester
connections
Standard values
—
High-voltage J/B
(in battery pack)
BATT OUT(-) ter-
minal
–
BATT IN(-)
terminal
10 k
or more
(No continuity)
Is the measured value within the range of standard value?
Go to step 7.
Replace the high-voltage J/B (in the battery
pack).