HYBRID/TROUBLE SHOOTING
3–168
1.
Connect the PCU harness (24P) connector and the HV battery
start relay.
2.
Disconnect the PCU harness (16P) connector.
3.
Set the starter key to the "ON" position.
4.
Using the electrical tester, measure the voltage between the lower-
side connector terminals of PCU harness (16P).
NO
YES
4
Inspecting the voltage of PCU wire harness (lower side)
SHTS03ZZZ0300114
Measurement
conditions
Tester
connections
Standard values
Starter key: ON
PCU harness (16P)
lower-side con-
nector
9th terminal
–
15th terminal
9 V or more
Is the measured value within the range of standard value?
Go to step 5.
Replace the PCU wire harness (lower side).