HYBRID/TROUBLE SHOOTING
3–775
1.
Remove the HV battery terminal block cover.
2.
Using the electrical tester, measure the resistance between the
terminals of high voltage J/B (in the battery pack) and high-voltage
J/B (in the ECU box).
NO
YES
6
Inspecting the DC high-voltage cable for continuity 2
BATT(-)
BATT(+)
BATT OUT(-)
BATT OUT(+)
SHTS03ZZZ0300506
Measurement
conditions
Tester
connections
Standard values
Starter key: LOCK
High-voltage J/B
(in battery pack)
–
High-voltage J/B
(in ECU box)
BATT OUT(+) ter-
minal
–
BATT(+)
terminal
BATT OUT(-) ter-
minal
–
BATT(-)
terminal
1
or less
(With continuity)
Is the measured value within the range of standard value?
Go to step 7.
Replace the DC high-voltage cable between
the high-voltage J/B (in the battery pack) and
the high-voltage J/B (in the ECU box).