HYBRID/TROUBLE SHOOTING
3–34
Idling stop cancel switch
(CAN reception)
Represents the idling stop cancel switch signal
input status. Idling stop cancel status ON = ON.
ON = 1 / OFF = 0
0 - 1
—
ABS activation signal
(CAN reception)
Represents the ABS activation signal input sta-
tus. ON = 1 / OFF = 0
0 - 1
—
Exhaust brake switch
(CAN reception)
Represents the retarder lever signal input sta-
tus. ON = 1 / OFF = 0
0 - 1
—
Motor temperature
Motor temperature
0 - 200
C
Inverter internal temperature
Inverter internal temperature
0 - 200
C
Starter key
Starter key status ON = 1 / OFF = 0
0 - 1
—
System main relay 3 (SMR3) state
Represents the system main relay 3 (SMR3)
output state. ON = 1 / OFF = 0
0 - 1
—
Clutch operation permission signal
Represents the clutch operation permission
state sent from the clutch ECU. Prohibit = 0 /
Enable = 1
0 - 1
—
HV battery leakage crest value
HV battery leakage crest value
0 - 4.995
V
Select lever position
(CAN reception)
Select lever position
AT-P = 0 / AT-RL = 1 / AT-N = 2 / AT-D = 3 /
AT-4 range = 4 / AT-3 range = 5 / AT-Others = 6
0 - 255
—
Clutch state (CAN reception)
Clutch state Engaged = 0 / partial clutch = 1 /
disengaged = 2 / unknown = 3
0 - 3
—
Shift transmission condition
(CAN reception)
Shift transmission condition OFF = 0 / UP = 1 /
DOWN = 2 / Changing gear = 3
HINT
The indication of "UP" means "Charging gear".
0 - 3
—
Vehicle driving mode
Vehicle driving mode Normal = 0, ECO = 1, PWR
= 2
0 - 2
—
System required torque
System required torque
-32,768 -
32,767
Nm
Turn signal light actuation signal
Turn signal light actuation signal OFF = 0, Right
turn = 1, Left turn = 2, Hazard = 3
0 - 3
—
Clutch oil temperature
Clutch oil temperature
-40 - 215
C
HV system coolant temperature
HV system coolant temperature
-128 - 127
C
HV battery cooling FAN drive
request duty
HV battery cooling FAN drive request duty
0 - 100
%
HV battery cooling FAN drive
request revolution
HV battery cooling FAN drive request revolution
0 - 10,000
r/min
HV battery cooling FAN revolution
HV battery cooling FAN revolution
HINT
Even if the HV battery cooling FAN drive
request revolution is 0 r/min, 0-100 r/min
appears.
0 - 10,000
r/min
HV battery cooling FAN revolution
voltage
HV battery cooling FAN revolution voltage
0 - 5
V
Item
Description
Display
range
Unit