HYBRID/TROUBLE SHOOTING
3–316
1.
Connect the inverter start relay and PCU harness (24P) connec-
tors.
2.
Disconnect the inverter cooling pump connector.
3.
Set the starter key to the "ON" position.
4.
Using the electrical tester, measure the voltage between the con-
nector terminals of inverter cooling pump.
NO
YES
7
Inspecting the voltage of PCU wire harness (lower side)
SHTS03ZZZ0300214
Measurement
conditions
Tester
connections
Standard values
Starter key: ON
Inverter cooling
pump connector
1st terminal
–
4th terminal
9 V or more
Is the measured value within the range of standard value?
Go to step 8.
Replace the PCU wire harness (lower side).