HYBRID/TROUBLE SHOOTING
3–206
5
Inspecting the
service plug 1
1. Disconnect the 1st and 2nd ter-
minals from the HV battery and
then remove the frame wire.
2. Using the electrical tester, mea-
sure the insulation resistance
between each terminal of frame
wire and the ground. (Do not
install the service plug.)
<Measurement conditions>
Starter key: LOCK
<Tester connections>
Frame wire
1st terminal
–
GND
2nd terminal
–
GND
<Standard values>
10 M
or more
The mea-
sured value is
within the
range of stan-
dard value: Go
to YES.
The mea-
sured value is
not within the
range of stan-
dard value: Go
to NO.
Go to step 6.
Replacing the
frame wire
(with a service
plug socket).
6
Inspecting the
service plug 2
1. Connect the 1st and 2nd termi-
nals to the HV battery and then
install the frame wire.
2. Using the electrical tester, mea-
sure the insulation resistance
between each terminal of frame
wire and the ground.
<Measurement conditions>
Starter key: LOCK
<Tester connections>
Frame wire
1st terminal
–
GND
2nd terminal
–
GND
<Standard values>
10 M
or more
The mea-
sured value is
within the
range of stan-
dard value: Go
to YES.
The mea-
sured value is
not within the
range of stan-
dard value: Go
to NO.
Replace the
HV battery.
Replace the
service plug.
P0A92 (TC29)
Abnormality in charging performance
Inspection Procedure
Step
Action
Description
Judgement
Check
(Yes/No)
Yes
No