HYBRID/TROUBLE SHOOTING
3–59
INSPECTION PROCEDURE: P0562 (TC71)
1.
Set the starter key to the "LOCK" position.
2.
Connect the diagnosis tool (HINO-DX) to the vehicle.
3.
Set the starter key to the "ON" position.
4.
In [Fault Information] on the diagnosis tool screen, check if DTC
P060B-B2 other than P0562-71 is detected.
NO
YES
1.
Set the starter key to the "LOCK" position.
2.
Disconnect the PCU harness (24P) connector.
3.
Using the electrical tester, measure the voltage between the vehi-
cle-side connector terminals of PCU harness (24P).
NO
YES
1
Reading the DTC [HINO-DX]
SHTS03ZZZ0300044
Is DTC P060B-B2 detected?
Perform troubleshooting for each of related
DTC.
Go to step 2.
2
Inspecting the vehicle wire harness
SHTS03ZZZ0300045
Measurement
conditions
Tester
connections
Standard values
Starter key: LOCK
PCU harness (24P)
vehicle-side con-
nector
2nd terminal
–
16th terminal
10
–
16 V
Is the measured value within the range of standard value?
Go to step 3.
Inspect the power supply circuit
([HV 10 A] fuse and wire harness).