HYBRID/TROUBLE SHOOTING
3–570
1.
Set the starter key to the "LOCK" position.
2.
Connect all the connectors that have been disconnected to restore
the system.
3.
Set the starter key to the "ON" position.
4.
Clear the malfunction history.
5.
Perform a test run (accelerate and decelerate running for approxi-
mately 1 hour).
6.
In [Fault Information] on the diagnosis tool screen, check if P0A2F-
33 is detected.
HINT
Monitor [Motor temperature] on the data monitor to check that the
temperature is less than 100
C {212
F}.
NO
YES
4
Reproduction check [HINO-DX]
SHTS03ZZZ0300369
Is DTC P0A2F-33 detected?
Replace the inverter.
The inspection is completed.