WARNING: Disconnect primary power prior to servicing.
Section 6 Troubleshooting
Platinum Z16HD+
6.9.2
VT100 - Page 1
Operational statuses and system information. Each line of the VT100 screen is listed
below. The parameter in bold, followed by possible statuses in parenthesis.
Figure 6-4 VT100 - Page 1
OPERATIONAL STATUS:
RF On: (ON/OFF) Status of the RF output, when “ON” there are no faults preventing
the signal from passing thru the BoostPro.
Mute Status: (ON/OFF) Status of the Mute condition for the BoostPro, when “OFF”
the BoostPro is not muting the signal.
Fast Mute Status: (ON/OFF) Status of the Fast Mute condition for the BoostPro, when
“OFF” the BoostPro is not muting the signal.
Fault Strike Status: (OK/FAIL) Status of the fault strike condition, when “OK” the
BoostPro has not entered or completed a three-strike fault condition: 3 separate
momentary fault conditions over a specified period of time, or a continuous fault
condition over a specified time. FAIL indicates a three-strike condition has occured and
the unit is faulted off.
Boost Bias Mode0: (LOW/HIGH) State of the line going to the PA module, see table
below for more information.
Boost Bias Mode1: (LOW/HIGH) State of the line going to the PA module, see table
below for more information.
Boost Bias Mode0
Boost Bias Mode1
Driver Stage
Output Stage
0
0
Class B
Class C
Summary of Contents for Platinum Z16HD+
Page 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...