9/15/06
888-2586-001
5-25
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignment
Platinum Z16HD+
5.14.4.1 Replacement Using EEPROM U39 From the Old Board
If the Master Controller needs to be replaced, but EEPROM U39 can be swapped from
the old board, then proceed as follows:
STEP 1
Shut the transmitter off and remove AC power from the transmitter.
STEP 2
Remove the defective Master Controller Board. Carefully remove U39.
STEP 3
Remove U39 from the new Master Controller Board and replace with the
EEPROM from the defective Master.
STEP 4
To transfer the Firmware ICs from the old board to the new on or to
simply install new firmware refer to "5.16 Removing/Replacing
Firmware ICs" on page 5-30, then return here.
STEP 5
Set all jumpers and dip switches on the new board according to the
listing below. Typical settings are:
•
S1-1 through S1-4 - Customer set RS-232 ID
•
S1-5 ON EEPROM mode select - must be ON for any IBOC mode.
•
S1-6 OFF (Factory Use Only)
•
S1-7 OFF (Not used)
•
S1-8 OFF (Factory Use Only)
•
S1-9 OFF (ON = Microcontroller RESET)
•
S1-10 ON (APC ON/OFF)
STEP 6
Install the new Master Controller Board and apply AC power to the
transmitter. It is a good idea to verify the transmitter configuration
settings in the Diagnostics Display.
NOTE:
To verify the most important configuration parameters, follow the steps listed
under "5.15.1 Configuration" on page 5-28, before continuing.
STEP 7
Turn the transmitter on and check the calibration. If the transmitter
calibration and configuration are okay, then this procedure is finished. If
not, then EEPROM U39 should be replaced and the procedure below
"Replacing EEPROM U39" should be performed.
5.14.5 Replacing EEPROM U39
If it is necessary to replace EEPROM U39, with the old Master Controller or with a new
Master Controller, the "5.15 System Configuration and Calibration" on page 5-28 will
have to be performed. However, since a new EEPROM is being installed a few
preliminary steps will have to be done first:
Summary of Contents for Platinum Z16HD+
Page 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...