WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 2 Installation & Initial Turn-On
Figure 2-10 PA Compartment Rear View
STEP 8
IPA Module configuration - The Platinum Z16HD+ has two IPAs active
at any given time, one for each Power Block. For the standard dual IPA
configuration, the IPA modules (each has 2 IPAs) will be identical to any
of the PA modules and may be plugged in with either side up in the IPA
slot. If the transmitter is configured for single IPA operation (one for
each Power Block), there will still be 2 IPA modules but each one will
only have an amplifier on one side. The other half of the module will be
empty. It is recommended that the single configuration IPA module be
inserted with the amplifier on the right side of the heatsink. This places
the amplifier in the IPA_AB1 position on the lower IPA and in the
IPA_CD2 position for the upper IPA, (the default for the controller). If
the IPA is on the left side of the heatsink when inserted, then IPA_AB2
and IPA_CD1 will have to be selected in the Configuration Menus
before operating the transmitter.
STEP 9
With all of the modules installed, the Fault LED on the controller front
panel should be flashing at this point. This indicates that there are
inactive faults in the fault log which need to be cleared next. To reset the
Fault Log press [FAULT, C, and then D for YES]. This will erase all
inactive faults in the Fault Log and the front panel Fault LED should be
off. If the “FAULT” LED on the front panel of the controller is not lit,
then proceed to the next step. If the “FAULT” LED, on the front panel of
the controller, is illuminated continuously (not flashing), use the Fault
A5
B5
C5
D5
B6
A6
B7
A7
B8
A8
C6
D6
C7
D7
D8
C8
Summary of Contents for Platinum Z16HD+
Page 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...