4-66
888-2586-001
9/15/06
WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 4 Overall System Theory
SAFE become active due to the signal MASTER_NORMAL(BAR) going high
when Life Support is initiated. This is discussed in the paragraphs labeled
MASTER_NORMAL(BAR).
d.
MSTR_NORMAL 1 applies a low to AND gate U25-2. This inhibits the Master
Controller from initiating a SYSTEM_MUTE which would mute the exciters and
the IPA.
e.
MSTR_NORMAL1 applies a low to NAND gate U7-2 causing U7-3 to go high.
This enables the direct connection of the front panel overlay buttons to the on and
off logic by enabling U26-13 and U26-2, bypassing the control circuits on the
failed Master Controller.
1.
When the OFF button is pressed, U26-1 will go high, causing U26-3 to go
high. This then passes through a series of OR gates, U31-8, U31-11 and
U33-6 and on to U16-10. This then connects to the RESET line on latching
relay K4, placing it in the position shown on the schematic. K4-13 will go
low, and this is sent through U16-12 and on to the Low Voltage Power Sup-
ply Board to relays K1 and K2. K1 and K2, will both open, shutting off the
AC (K1 applies AC to the contactor coil, while K2 applies AC to the RF
Source).
2.
The high at U26-13 enables the XMTR_ON_LOW pushbutton on the front
panel overlay when in Life Support Mode to enable the local transmitter
ON LOW command. Remote ON LOW (REM_ON_LOW) is also avail-
able in Life Support Mode. Note that the HIGH ON pushbutton on the front
panel overlay has no function when in Life Support Mode.
f.
MSTR_NORMAL1 applies a low to all nine AND gates in both U12 and U14.
This prevents the Master Controller from applying exciter and precorrector
mutes, exciter and precorrector selects or IPA select signals.
MASTER_NORMAL(BAR)
This signal goes high when the Master Controller fails. It causes the following actions
to occur:
a.
MASTER_NORMAL(BAR) applies a high to AND gate U6-2. This enables the
fault, LS_SYST_FAULT (Life Support System Fault) only while in Life Support
Mode. This fault is caused by excessive VSWR or IPA Current and will shut the
transmitter off.
b.
MASTER_NORMAL(BAR) applies a high to OR gate U32-5. This enables the
remote command, REM_ON_LOW(BAR) so the transmitter can be turned on by
remote control when the Master Controller has failed. Note that the
REMOTE_ON_LOW(BAR) command can be disabled, during normal operation,
by placing the controller in LOCAL mode using the front panel REMOTE DIS-
ABLE pushbutton. This disables the remote ON command via the
REM_ON_ENABLE signal at U32-4. If the Controller is in LOCAL mode, U26-
Summary of Contents for Platinum Z16HD+
Page 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...