WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignment
Platinum Z16HD+
Table 5-1 EEPROM U39 Default Parameter Checklist
Platinum Z16HD+ Transmitter
Parameter
FM+HD Mode
Default Settings
HD Mode
Default Settings
Forward Factor
0.015393
Reflect Factor
0.000613
CAL Frequency
Set to your frequency
(Default = 98MHz)
Operating Frequency
Set to your frequency
(Default = 98MHz)
Cal APC Factor
15.15
100% TPO Set
7000W
3500W
Max High Set
7350W
3675W
Max Low Set
3500W
1750W
UPS Setting
3500W
1750W
Low Power Alarm
User Configurable
VSWR Foldback
1.30
VSWR Fault
1.70
NOTE: These are typical values: Refer to Factory Test Data for calibration purposes.