System configuration and calibration is mainly for setting the transmitter up for the first
time by factory personnel. The procedures contained here should NOT be done as part
of a routine maintenance or adjustment schedule. The following procedure should only
be done if the Master Controller Board has to be replaced and/or the EEPROM U39 on
the old Master Controller Board is bad or suspect (EEPROM U39 is the memory chip
which contains all of the configuration and calibration settings). Otherwise replacement
of the Master Controller Board can be accomplished by swapping U39 from the old
board to the new one. See "5.14.4 Replacing the Master Controller Board" on page 5-24
before proceeding.
The procedure will be broken up into two sections:
a.
Configuration
b.
Calibration
5.15.1 Configuration
The transmitter should be turned off, but with AC power applied from the wall breaker.
The REMOTE DISABLED LED should be lit on the front panel of the transmitter. For
the following setup refer to the Diagnostics Display Menu Tree for more details of how
to get to System Calibration and Setup screens referred to below.
NOTE:
For the following procedures do not press [HOME] or [BACK] unless specifi-
cally told to do so.
STEP 1
Press [HOME, MORE, CONFIGURATION, A] From here the following
System choices need to be made:
•
RF SOURCE 1: HD-EXC, ANALOG, or BSTAMP
•
RF SOURCE 2: HD-EXC, ANALOG, BSTAMP, or N/A. Use N/A if
an alternate RF source is not used.
STEP 2
Press [MORE] and then continue below.
•
AC PHASE - Select "1" phase or "3" phase to match your transmitter
power supply configuration.
•
UPS/RFSOURCE - This is the configurable remote input at TB1-9. Set
for UPS if the low power UPS mode is to be used, or to EXC if it is
going to be used as a remote RF Source select.
•
FAN SPEED - This should be set to AUTO, otherwise the fan will stay
on HIGH speed all the time.
Summary of Contents for Platinum Z16HD+
Page 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...