4-28
888-2586-001
9/15/06
WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 4 Overall System Theory
Figure 4-12 Single Phase PA Power Supply
Simplified Soft-Start and Discharge
4.5.1.2.2 PA Power Supply Discharge
The PA Power Supply Discharge circuit also uses the Soft Start resistor to discharge the
52Vdc PA supply. The discharge circuit is activated when the transmitter is turned off.
To discharge the power supply, the 52Vdc supply output is connected to the discharge
resistor through a pair of MOSFET switches. When the discharge circuit is active, it
disables the SCRs to prevent the supply from trying to turn on during a discharge cycle.
4.5.1.2.3 16VCT Secondary
There is a 16VCT secondary on each transformer whose output goes to the Rectifier
Board for that supply. It is rectified and used as the drive for the gates of the SCRs. This
is required due to the large gate drive current needed on the large single phase SCRs.
The rectified voltage from this secondary is called V+SCR on the Rectifier Board. It is
also fused on the Rectifier Board.
4.5.2
Low Voltage Power Supply
The Low Voltage Power Supply is a single PC board mounted in the rear of the
transmitter near the main contactor. It is designated A19 (assembly 19). The circuit
board is the same for the 3-phase and single phase configurations, only the AC wiring to
and from the board is changed. It supplies DC voltages to all circuits in the transmitter.
These include:
•
+20Vdc
Summary of Contents for Platinum Z16HD+
Page 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...