9/15/06
888-2586-001
5-33
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignment
Platinum Z16HD+
STEP 10
Locate A1J2 and A1P2 on the left hand side of the chassis between the
transformers and disconnect.
STEP 11
Slowly roll the power supply approximately 3/4 of the way out being
careful not to snag any wiring or ribbon cables.
STEP 12
Disconnect W12 from its rectifier board, then remove the power supply
completely.
STEP 13
Located above the power supply is a cage or basket that covers the entire
combiner. This can be removed by removing the perimeter screws.
Lower the basket and remove it from the transmitter.
STEP 14
You can now see the combiner assembly. Go to rear of the transmitter
and you can see the two 1 5/8 inch combiner outputs (one on the left
hand side and one right hand side) feeding the combiner assembly. At
the rear center is the output. The 3 1/8 inch output connector is socketed,
there are no hose clamps or hardware that needs to be removed to pull
this filter out.
STEP 15
Disconnect the output transmission line from the top of transmitter and
disconnect J3, J4, J5 from the directional couplers. Disconnect the top
plate and connector assembly from the transmitter so that the filter can
be raised up about 6 inches. Loosen the two hose clamps holding the
filter in place and slide it up and out of the combiner. Then tighten the
hose clamps to hold the filter up.
STEP 16
Disconnect W143 from J4 on the combiner. With one man in front and
one man at the rear to support the combiner loosen the two hose clamps
for the combiner outputs and remove the hardware at each corner of the
hybrid assembly. Remove the combiner output support bracket by
removing two screws located to the rear of the lower hose clamp of the
Low Pass Filter. Slowly and evenly lower the combiner from the
transmitter disengaging it from the combiner outputs. You will need to
spread the combiner mounting brackets to completely remove it from
the transmitter.
STEP 17
With the combiner on a good work surface turn the unit upside down and
remove 32 screws from the cover. Remove the cover and this will
expose the internal workings of the combiner.
To re-install the power supply refer to Section 2, Installation.
Summary of Contents for Platinum Z16HD+
Page 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...