WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignment
Platinum Z16HD+
STEP 3
Adjust R25, Manual PWR Reference on the Life Support Board for 25%
of the default rated power (of your primary modulation format) on the
external meter.
STEP 4
Switch S1-9 to OFF and the transmitter should return to your normal
TPO. It may be necessary to raise or lower power slightly.
5.12 Forward Power Calibration
Forward power calibration must be performed upon replacement of the Life Support or
Master Controller boards, or the Directional Coupler. To correctly re-calibrate your
transmitter follow the procedure below.
It is recommended that the transmitter be calibrated using the desired TPO for your
primary modulation format (FM, HD, FM+HD, or SLC).
NOTE:
The following Forward Power Calibration procedure requires an external power
meter to be used as the calibration reference.
STEP 1
Shut the transmitter off. Press [HOME, MORE, CONFIGURATION, D]
and set your operating frequency.
STEP 2
Go to the 100% TPO SET screen [HOME, MORE, CONFIGURATION,
B, B] Then choose the desired modulation format. Set this screen to read
the power at which you are going to calibrate (your TPO). If you wish to
restore to factory values, refer to Factory Test Data for your transmitter
values, or see Table 5-2 on page 5-36 for default values.
STEP 3
Press [HOME, MORE, CONFIGURATION, B, C] Then choose the
desired modulation format. This should take you to the MAX HIGH
SET screen. Make a note of the setting and then change it to your
maximum output for this procedure. Press [BACK] to update the
information.
STEP 4
Press [HOME, MORE, CONFIGURATION, C, A, B]. This should take
you to the Forward Factor screen in Figure 5-3. If necessary edit this
screen to read 0.015393. To access the edit controls press and hold [D]
and press [C]. Press [BACK] to update the setting.
Summary of Contents for Platinum Z16HD+
Page 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...