2-30
888-2586-001
9/15/06
WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 2 Installation & Initial Turn-On
STEP 12
Press the HIGH power ON button on the front panel of the controller. If
there are no faults, again verify all of the transmitter display readings
against those in the factory test data sheet.
STEP 13
This is optional, as it simply makes the transmitter FWD PWR % meter
read 100% at the customer specified Transmitter Power Output (TPO),
which should already be factory set. This will not change the kW
reading on the FWD PWR display.
a.
Set the power to the desired TPO using the raise and lower buttons.
b.
Go to the 100% TPO SET screen [HOME, MORE, CONFIGURA-
TION, B, B] then select your desired modulation format and set the
power level to your TPO. Press [BACK] to update and store the new
information. Repeat this step for all possible desired modulation for-
mats.
c.
The front panel FWD PWR reading should be 100%. You may also
want change the MAX HIGH and MAX LOW power settings to
something more in line with your new TPO as well. MAX HIGH sets
the maximum power level when the HIGH ON button is pressed,
while MAX LOW sets the maximum power level when the LOW
ON button is pressed. The procedure for changing power limits is
given in Section V, Maintenance and Alignments.
The initial turn on is now complete.
Summary of Contents for Platinum Z16HD+
Page 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...