9/15/06
888-2586-001
4-45
WARNING: Disconnect primary power prior to servicing.
Section 4 Overall System Theory
Platinum Z16HD+
Table 4-2 RFL PWR CAL Values for All ZHD+ Transmitters
NOTE:
Tolerances for the values in above Table 4-2 are +/-10W. Also note, in some GUI
display menus power levels are shown in kW (Example: 80W will be displayed
as 0.08 kW).
The following is a description of each of the Calibration and A/D parameters. Values
used are for discussion purposes only. Generic formulas are in bold text. For
alignment purposes, use the actual numbers for your transmitter that are logged onto the
Factory Test Data. Table 4-1, and Table 4-2 below show default Factors for all ZHD+
transmitters. These may be used for the math calculations in the following section, to
determine approximate values for your transmitter.
4.8.2.1
DAC_APC_REF
DAC_APC_REF [HOME, MORE, CONFIGURATION C, B] is a counter (internal to
the micro), whose output will be between 0 and 900, that is controlled by the RAISE
and LOWER buttons on the front panel. RAISE increases the count and LOWER
decreases the count. This number is then D/A converted to get the APC_REF voltage
Table 4-1 Default Cal Factors for All ZHD+ Transmitters
Z4HD+
Z6HD+
Z8HD+
Z12HD+
Z16HD+
Forward Factor
0.003079
0.005388
0.007697
0.011545
0.015393
Reflect Factor
0.000123
0.000225
0.000306
0.000460
0.000613
Cal APC Factor
3.03
5.30
7.58
11.36
15.15
Model
FM+HD
Mode
HD
Mode
Z4HD+
50W
30W
Z6HD+
80W
40W
Z8HD+
110W
50W
Z12HD+
150W
80W
Z16HD+
210W
110W
Summary of Contents for Platinum Z16HD+
Page 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...