4-30
888-2586-001
9/15/06
WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 4 Overall System Theory
a different secondary tap. The taps closest to the center will provide the least amount of
secondary turns in circuit and will therefore give the lowest DC output voltage. This
means that the taps which are furthest from the center will give the highest DC output
voltage due to more active turns in the secondary.
There are two rectifier boards mounted on the top of each power transformer. There is
an “A” side and a “B” side, both of which are shown on the same schematic. The left
side of the schematic is the “B” side and the right side is the “A” side (except on sheet 3
which is “B” side only). There is also only one part number for both boards. The “A”
Rectifier Board is for the transformer secondary “A” with the “B” Rectifier Board used
with transformer secondary “B”. The Rectifier Boards are operated in parallel and are
tied together by a ribbon cable, J3, which is shown in the middle of the schematic
connecting the “A” and “B” sides.