9/15/06
888-2586-001
6-5
WARNING: Disconnect primary power prior to servicing.
Section 6 Troubleshooting
Platinum Z16HD+
6.7
Fault Log
The Fault Log is in the “FAULT” menu of the Diagnostics Display. To access the Fault
Log press [MORE, FAULT, D]. This should bring up the screen shown in Figure 6-2.
This screen shows the latest of a possible 32 faults (the maximum number of faults
which can be stored in the log) as designated by “LOG No. 1 of n”, where "n" would be
the total number of faults present. “Type” gives the name of the fault. “Time” gives the
elapsed time since the fault occurred, not the actual time at which it occurred. “Status”
tells you whether the fault is active or non-active. Pressing A or PREV (Previous), will
take you to the next fault in the log.
Figure 6-2 Fault Log
6.7.1
Front Panel Fault LED
When a fault is detected the Fault LED on the front panel of the controller will
illuminate a steady red as long as there is an active fault. If there are faults in the log,
but none are active, the Fault LED will flash to alert the technician to check the Fault
Log.
6.7.2
Fault Reset
Press [HOME, FAULT, C]. This screen, shown in Figure 6-3, allows access to the Fault
Reset. Note the warning asking if you really want to erase the faults in the log, just in
case this screen was reached by accident. Pressing YES [D] will erase any of the faults
in the Fault Log which are inactive (an active fault cannot be erased). Pressing NO [C]
will simply take you back to the previous MENU without erasing the fault log.
Summary of Contents for Platinum Z16HD+
Page 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...