5-24
888-2586-001
9/15/06
WARNING: Disconnect primary power prior to servicing.
Platinum Z16HD+
Section 5 Maintenance and Alignment
a.
For PSC #1 - All switches OFF
b.
For PSC #2 - S1-1 = ON, all other switches OFF
c.
JP1 pins 1-2 (Both Controllers)
d.
JP2 pins 1-2 (Both Controllers)
5.14.3 Replacing a PA Controller Board
Replacement of a PA Controller Board requires no analog adjustments. Set all dip
switches and jumpers to the same position as the board being replaced. If the new board
does not have the firmware ICs already installed, then the firmware will have to be
transferred from the old board. Refer to "5.16 Removing/Replacing Firmware ICs" on
page 5-30.
The following is a listing of the normal dipswitch settings for S1 on each PA Controller:
a.
For PAC #1 - All switches OFF.
b.
For PAC #2 - S1-1 = ON, all other switches OFF.
c.
For PAC #3 - S1-2 = ON, all other switches OFF
d.
For PAC #4 - S1-1 and S1-2 = ON, all other switches OFF.
NOTE:
The switches set the board ID #. Once the ID for the board has been set, it must
be placed in the proper slot and the correct cables connected to that # controller.
An improper ID or incorrect cabling will generate cable or jumper faults in the
Fault Log and the transmitter will not turn on.
5.14.4 Replacing the Master Controller Board
In the unlikely event that the Master Controller Board needs to be replaced, there are
two possible scenarios:
a.
Replacement using EEPROM U39 from the old board. This procedure should be
tried first.
b.
Replacement when using a new EEPROM U39
In either case the firmware ICs U18 and U28 will have to be transferred from the old
board or be replaced with new. EEPROM U39 contains all of the configuration and
calibration settings for the transmitter including configuration, software calibration
settings, power levels and fault limits etc.
Summary of Contents for Platinum Z16HD+
Page 4: ...MRH 2 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 6: ...9 15 06 888 2586 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2586 001 9 15 06 WARNING Disconnect primary power prior to servicing ...